Dry-type transformer manufacturer: working principle of dry-type isolation transformer
Dry-type transformer manufacturersIntroduction, dry-type isolation transformer is widely used in AC 50Hz to 60Hz, voltage below 660V circuit. The various input and output voltages of the product, the connection group, the number and position of the adjustment tap (usually ± 5%), the distribution of winding capacity, the configuration of the secondary single-phase winding, the use of the rectifier circuit, and whether the housing is required, can be carefully designed and manufactured according to user requirements.
Working principle of 1. dry-type isolation transformer
Dry-type transformer manufacturers said that the principle of dry-type isolation transformer is the same as that of ordinary transformers, using the principle of electromagnetic induction. An isolation transformer usually refers to a 1:1 transformer. Since the secondary coil is not grounded, there is no potential difference between the wire in the secondary coil and the ground, which makes the instrument safer and is usually used for power maintenance. Not all isolation transformers are 1:1 transformers. The power supply of control transformers and electronic tube equipment also belongs to isolation transformers, which are widely used in air conditioning, maintenance and other fields.
Function of 2. type isolation transformer
Dry-type transformer manufacturerssaid,Dry-type isolation transformers are mainly used to isolate electrical equipment from the grid for safety or anti-interference requirements. The electrical equipment has no direct electrical connection to the power supply. The two coils on the primary side and the secondary side of the isolation transformer are not directly electrically connected, and electromagnetic-to-electrical conversion is performed by a magnetic field. In this way, the odd harmonics on the primary side can form a loop current in the primary side winding through the delta connection of the primary side three-phase winding, and will not flow to the secondary side, thereby reducing harmful harmonics in the power grid.
Application of 3. Dry-type Isolation Transformer
1. Isolation transformer (delta/star) connected to the power input terminal
1. If the third harmonic and interference signal of the power grid are serious, the △/Yo isolation transformer can be used to remove the third harmonic and reduce the interference signal.
2.△/Yo isolation transformer can be used to generate new neutral line, so that the equipment has nothing to do with the neutral line of the power grid, and avoid abnormal operation of the equipment due to poor neutral line of the power grid.
3. The current waveform distortion caused by nonlinear loads (such as third harmonics) can be isolated without polluting the power grid.
2. Isolation transformer (star/delta) connected to the output of the power supply
1. Prevent nonlinear load current distortion, affect the normal operation of the regulated power supply and return to the grid, and play a role in purifying the grid;
2. Nonlinear load current distortion affects sampling accuracy. You can sample/△ isolation transformer at the input of Yo to obtain a control signal that can reflect the actual situation, so that the regulated power supply can be controlled normally;
3. If the load is unbalanced, the use of Yo/△ will not affect the normal operation of the regulated power supply.
Keyword:
Ted Letter Door Industry
Related News
Distribution box manufacturer: What is the clearance of electrical equipment in distribution box?
Distribution box manufacturer: What is the clearance of electrical equipment in distribution box? Because the cable sheath raw material (composite resin) around the metal conductor is electrically conductive, it may cause the cable sheath raw material to exhibit induced electrification, in other words, breakdown voltage.
The distribution box manufacturer said that after the explosion-proof distribution box is connected to the switching power supply, many people will check whether the route of the explosion-proof distribution box is plugged in. At this time, even if the explosion-proof distribution box has factory inspection, do not directly use hand touch or body contact, but it is safe not to remove all places. In addition, when the explosion-proof distribution box is in operation, it is impossible to disassemble and assemble. First, disconnect the switching power supply, and then use the test pen to detect that there is no switching power supply, in order to carry out disassembly, assembly and operation and maintenance work.
Distribution box manufacturers said that in recent years, with the rapid development of science and technology at the level of substation equipment, the demand for substation equipment is getting higher and higher. The distribution box manufactured by the distribution box manufacturer is an indispensable part of the substation equipment, and it is also very important to update and transform it. In order to adapt and facilitate the knowledge of electricity safety, the distribution box looks very important. All aspects of the distribution box must be improved. The improvement of the distribution box starts from the following aspects:
Dry-type transformer manufacturers: dry-type transformer selection techniques
Dry-type transformer manufacturers said that the safe operation and service life of dry-type transformers largely depend on the safety and reliability of the insulation of the transformer package components. The heat and cold of the package components exceed the heat and cold of the insulation and damage the insulation, which is one of the main reasons for the normal operation of the transformer. Therefore, it is very important to monitor and alarm the working cold and hot of the transformer.
Dry type transformer manufacturers: dry type transformer is what?
Dry-type transformer manufacturers, dry-type transformers are widely used in local lighting, high-rise buildings, airports, terminals, CNC machinery and equipment and other places. Simply put, a dry-type transformer refers to a transformer in which the iron core and windings are not immersed in insulating oil.
Dry-type transformer manufacturer: working principle of dry-type isolation transformer
Dry-type transformer manufacturers, dry-type isolation transformers are widely used in AC 50Hz to 60Hz, voltage below 660V circuit. The various input and output voltages of the product, the connection group, the number and position of the adjustment tap (usually ± 5%), the distribution of winding capacity, the configuration of the secondary single-phase winding, the use of the rectifier circuit, and whether the housing is required, can be carefully designed and manufactured according to user requirements.