Dry type transformer manufacturers: dry type transformer how to check?


What is the connection mode of dry-type transformer?Dry-type transformer manufacturersTo introduce you!

1. Use a megohmmeter to test the insulation resistance of the "input" and "output" terminals of the short-circuit transformer. When measured with a 1000V megohmmeter, the resistance value is greater than 2M ohms.

2. The cross-sectional wiring of the input and output power lines of the transformer should meet the requirements of its current value; according to the current density of 2-2.5A/min2.

  3.Dry-type transformer manufacturers said,The input and output three-phase power lines are connected to phase A, phase B and phase C respectively according to the bus color of the transformer wiring board, green and red. The neutral line is connected to the neutral zero line of the transformer voltage, and the grounding line, the transformer shell and the transformer center point are connected. Usually, the grounding line and the neutral line are led out from the neutral point of the transformer. (If the transformer has a cabinet, it should be connected with the grounding mark of the cabinet). Check the input and output lines to make sure they are correct.

4. Turn on the power supply with no load first, observe and test the input and output voltages to meet the requirements, and observe whether the machine has abnormal noise, lights, odors and other abnormal phenomena. If there is any abnormality, please disconnect the input power immediately.

5. After the no-load test is completed and normal, the load can be connected.

How to check dry type transformer?

1. Any abnormal sound and vibration. 2. Whether there is local overheating, harmful gas corrosion, etc., causing the insulation surface to change color due to creepage and carbonization. 3. Whether the transformer air cooling device operates normally. 4. High and low pressure joints shall not be overheated. The cable head shall be free of leakage and creepage. 5. Monitor the temperature rise of the winding according to the insulation material grade of the transformer, and the temperature rise should not exceed the specified value. 6. The supporting porcelain bottle should be free of cracks and discharge traces. 7. Check whether the winding pressing parts are loose. 8. Indoor ventilation, iron core air duct should be free of dust and debris, iron core should be no rust.

Dry-type transformer manufacturers, with the promotion and application of dry-type transformers, its manufacturing technology has also made great progress, it is foreseeable that the future of dry-type transformers will be further developed in the following areas.

Energy-saving and low-noise: With the introduction of new low-consumption silicon steel sheets, foil-wound structures, stepped iron core joints, environmental protection requirements, in-depth noise research, and computer optimization design and other new materials, new processes and new technologies, dry-type transformers will be more energy-efficient and quiet in the future.

High reliability: improving product quality and reliability will be the unremitting pursuit of people.

Environmental characteristics certification: according to the European standard HD464. Weather resistance (C0, C1, C2), environmental resistance (E0, E1, E2) and fire resistance (F0, F1, F2) of dry-type transformers are studied and certified.

Large capacity: from 50~2.500 kVA distribution transformer dry-type transformer to 10000~20000 kVA/35kV power transformer, with the continuous increase of urban power load, urban network area substation is more and more deep into the city center, residential areas, large factories and mines and other load center, large capacity 35 kV power transformer for community center power supply will be widely used.

Multi-function combination:Dry-type transformer manufacturers said,From a single transformer to air-cooled, protective sleeve, temperature computer interface, zero-sequence transformer, electric energy metering, closed bus, side outgoing multi-functional combination transformer. It is foreseeable that the distribution transformer in the 21st century will be a resin-insulated dry-type transformer with superior performance, low noise and energy saving.

Keyword:

Ted Letter Door Industry

Related News


Distribution box manufacturer: What is the clearance of electrical equipment in distribution box?

Distribution box manufacturer: What is the clearance of electrical equipment in distribution box? Because the cable sheath raw material (composite resin) around the metal conductor is electrically conductive, it may cause the cable sheath raw material to exhibit induced electrification, in other words, breakdown voltage.


Distribution box manufacturers: explosion-proof distribution box actual operation should pay attention to what key points?

The distribution box manufacturer said that after the explosion-proof distribution box is connected to the switching power supply, many people will check whether the route of the explosion-proof distribution box is plugged in. At this time, even if the explosion-proof distribution box has factory inspection, do not directly use hand touch or body contact, but it is safe not to remove all places. In addition, when the explosion-proof distribution box is in operation, it is impossible to disassemble and assemble. First, disconnect the switching power supply, and then use the test pen to detect that there is no switching power supply, in order to carry out disassembly, assembly and operation and maintenance work.


Distribution box manufacturers: stainless steel distribution box should be how to achieve the ideal state?

Distribution box manufacturers said that in recent years, with the rapid development of science and technology at the level of substation equipment, the demand for substation equipment is getting higher and higher. The distribution box manufactured by the distribution box manufacturer is an indispensable part of the substation equipment, and it is also very important to update and transform it. In order to adapt and facilitate the knowledge of electricity safety, the distribution box looks very important. All aspects of the distribution box must be improved. The improvement of the distribution box starts from the following aspects:


Dry-type transformer manufacturers: dry-type transformer selection techniques

Dry-type transformer manufacturers said that the safe operation and service life of dry-type transformers largely depend on the safety and reliability of the insulation of the transformer package components. The heat and cold of the package components exceed the heat and cold of the insulation and damage the insulation, which is one of the main reasons for the normal operation of the transformer. Therefore, it is very important to monitor and alarm the working cold and hot of the transformer.


Dry type transformer manufacturers: dry type transformer is what?

Dry-type transformer manufacturers, dry-type transformers are widely used in local lighting, high-rise buildings, airports, terminals, CNC machinery and equipment and other places. Simply put, a dry-type transformer refers to a transformer in which the iron core and windings are not immersed in insulating oil.


Dry-type transformer manufacturer: working principle of dry-type isolation transformer

Dry-type transformer manufacturers, dry-type isolation transformers are widely used in AC 50Hz to 60Hz, voltage below 660V circuit. The various input and output voltages of the product, the connection group, the number and position of the adjustment tap (usually ± 5%), the distribution of winding capacity, the configuration of the secondary single-phase winding, the use of the rectifier circuit, and whether the housing is required, can be carefully designed and manufactured according to user requirements.